Row1

CMIS, On-site inspections and certifactions of pressure equipment

CMIS, On-site inspections and certifactions of pressure equipment

Services – Design Verification

Colin Mongta Inspection Services Pty Ltd provide a design verification service complying with the requirements of AS3920 (Assurance of product quality) Part 1: (Pressure equipment manufacture) for the following design codes: AS1210, AS1228, EN5500, ASME Section 1 and VIII Div 1 & 2, New Zealand Code of Practice.

The Occupational Health & Safety Regulations 2007.

Schedule 2
PART 1—PLANT REQUIRING REGISTRATION OF DESIGN

Pressure equipment, other than pressure piping.
ie: Boiler or pressure vessel of Hazard Level – A, B, C or D, as determined by AS4343.

AS3920.1 Clause 4.5 DESIGN VERIFYING BODY
4.5.1 Requirements The design verifying body shall be either a regulatory authority or a body acceptable to the authority. If the body is other than the regulatory authority, it shall comply with the following requirements:

  1. Be competent with all necessary facilities, organizations and staff to undertake competent verification of the particular design.
  2. Employ external design verifiers who—
    • hold a degree or equivalent in an appropriate engineering discipline plus at least two years relevant experience in the design or design review of pressure equipment;
    • hold a certificate or equivalent in an appropriate engineering discipline plus at least four years relevant experience in the design or design review of pressure equipment; or
    • Have other qualifications or experience acceptable to a certifying body.
  3. Comply with the requirements equivalent to the requirements for the acceptance of Inspection bodies in SAA HB18.39 (ISO/IEC Guide 39).
  4. Have a quality system complying with SAA HB18.39 (or AS/NZS ISO 9001 or AS/NZS ISO 9002) and this Standard; and certified by a certifying body.
  5. Have no involvement in the design other than for verification.
  6. Be an organization other than that of the designer, manufacturer, purchaser, owner, supplier, importer, or user.

AS3920.1 Clause 4.4 EXTENT OF DESIGN VERIFICATION
The following aspects of the design shall be verified:

  • Materials.
  • Adequacy of all pressure parts, considering all service conditions specified in the relevant Standard or purchaser’s specification or both.
  • Supports where applicable.
  • Manufacture and testing requirements.
  • Specifications for flanges, valves and fittings (if such components are provided with the pressure equipment).
  • Any other aspects of the design which, in the opinion of the external design verifier, are essential for verification in accordance with Clause 4.3.